Technical data

Key data at a glance!

The HV unit is perfectly tuned. The heat pump has a high coefficient of performance (COP).

Technical data   LI 4
Recommended for buildings with a heat output at -14°C outside temperature kW max. 1 to 4
HEAT PUMP    
Operating limit air temperature °C -16 to +35
Max. heat pump flow / min. return flow temperature °C 55/25
Air volume flow outside air/outgoing air m³/h 1500
Compression available externally outside air/outgoing air Pa 20
Heating water flow rate recommended/internal pressure loss (at dT 10K=approx. 0.1 better COP) m³/h / bar 0.8/0.06
Heating water flow rate max./internal pressure loss (at dT 5K) m³/h / bar 1.6/0.20
Nominal heat output/coefficient of performance A7/W35 kW/COP 5.40/4.91
Nominal heat output/coefficient of performance A7/W45 kW/COP 5.10/3.92
Nominal heat output/coefficient of performance A2/W35 kW/COP 4.50/4.09
Nominal heat output/coefficient of performance A2/W45 kW/COP 4.30/3.58
Nominal heat output/coefficient of performance A-7/W35 kW/COP 3.20/3.37
Nominal heat output/coefficient of performance A-7/W45 kW/COP 3.10/2.82
Power consumption scroll compressor A2/W35 kW 1.10
Refrigerant /filling quantity type/g R134a/2000
DIMENSIONS, CONNECTIONS, WEIGHT    
Dimensions H/W/D cm 108x65x75
Air connections heat pump outside air/outgoing air DN 400
Condenser-storage tank connections DN 1 1/4" IG
Condensate connection (hose) DN 3/4"
Weight approx. kg 180
ELECTRIC CONNECTION    
Rated power/protection kW/A 5.88/C16
Operating current scroll compressor A 6
Starting current scroll compressor A 32
Voltage/frequency V/Hz 400/50
Protection class according to EN 60529 IP 20
SOUND LEVEL LpA at 1 m distance with 100% HP    
Noise radiation housing dB(A) 52
Duct “to outdoor” without silencer dB(A) 68
MISCELLANEOUS    
Housing   steel sheet
Colour   white
Place of installation   inside
 